Download materials
Download materials
Nexo Mini PLC
CÓD: NES12-DR
Description
Description
Mini Nexo PLC, developed for the automation of small systems and machines, offering practicality, reliability, and easy integration. Compact and versatile, it is ideal for applications requiring efficient control in a reduced space.
- Models with different numbers of inputs and outputs (8 to 14 inputs / 4 to 8 outputs)
- Configurable AC or digital inputs (including DI/DO)
- Relay outputs with voltage options (12/24V or 110/240VAC)
Select the options below
Code list
Code list
| Code | Description |
|---|---|
| NES12-DR | 12/24VAC / 8 Inputs (4 DI/AI and 4 DI)/4 Relay Outputs |
| NES22-DR | 12/24VAC / 14 Inputs (6 ED/EA and 8 ED)/8 Relay Outputs |
| NEX14-AR | 110/240VAC / 10 AC Inputs/4 Relay Outputs |
| NEX18-AR | 110/240VAC / 12 AC Inputs/6 Relay Outputs |
General specifications
General specifications
| Model | NEX-18DR | NEX-18W-DR-E | NES12-DR | NES22-DR |
|---|---|---|---|---|
| Supply voltage | 10.8 ~ 28.8 VDC | 24 VDC | 10.8 ~ 28.8 VDC | 24 VAC |
| Consumption | 50 mA (max.) | |||
| Standards compliance (with the Low Voltage Directive and EMC Directive) | IEC/EN 61131-2, IEC/EN 61131-2 (zona B), IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3 and IEC/EN 61000-6-4 | |||
| Mechanical resistance | Vibrações: IEC/EN 60068-2-6: 5 ~ 8.4 Hz (amplitude constante 3.5 mm) Vibrações: IEC/EN 60068-2-6: 8 ~ 84 Hz (amplitude constante 3.5 mm) Shock: IEC/EN 60068-2-27: 8 ~ 150 Hz (acceleration constante 1 g) Shock: IEC/EN 60068-2-27: 8.4 ~ 150 Hz (acceleration constante 1 g) | |||
| Operating temperature | -20 ~ 55 °C | |||
| Storage temperature | -40 ~ 70 °C | |||
| Ambient humidity | 10 ~ 95% RH, non-condensing | |||
| Mounting | DIN rail TS35, 4MW, or wall mounting | |||
| Interface | 6 buttons for user interaction | 5 buttons for user interaction | 6 buttons for user interaction | |
| Programming method | Ladder logic with software per IEC61131 | |||
| Clock data retention | 20 days (25 °C) | |||
| LCD display | Graphic - 4 lines of 16 characters | |||
| Digital input logic | PNP | |||
| Analog input resolution | 10 bits | |||
| Analog input isolation | Not isolated | |||
| Relay outputs - CPU | 1NO - 10A - 250 VAC - Max. load 6V - 1A | |||
| Relay outputs - expansions | 1NO - 3A - 250 VAC - Min. load 6V - 1A | |||
| Ethernet port | Modbus TCP/IP communication protocol | |||
| Serial port | RS232 or RS485 - ModbusRTU master or slave communication protocol | |||